MIROM Medical & Research Equipment Ltd. MIROM Medical & Research Equipment Ltd.
MIROM Medical & Research Equipment Ltd.


About us

Products

Manufacturers

News

Contact us

List of RFQ

Home
Search Products


Choose Category


search /
ISO 9001:2000

BVQI ISO:9001

Our Products

For a quotation select the item(s) by Add to RFQ. View the selected list via List of RFQ and then send it by Send RFQ.

Products > RESEARCH > Stimulators


Add to RFQ

Model: CK-100    Cat.No.: CK-100
Manufacturer: iWORX

8-Channel High Voltage Output stimulators designed for use in experiments involving organ or tissue baths. Each channel can deliver up to 10mA of current at a preset voltage up to 100V. Voltage amplitudes are set independently on each channel using a calibrated 10-turn readable dial and are accurate to 2% of the set value. Complex patterns of stimulation to be executed either manually or from any TTL source. Output Control: remote via logic or manual control.
Also is available model CK-100E - on which the current limit is set to 40mA on each channel, or 100mA if only one channel is used.
Download pdf User Manual.


Add to RFQ
Details

Model: BSI-950    Cat.No.: BSI-950
Manufacturer: ADInstruments

Biphasic Stimulus Isolator.
An economical analog-input - analog-output stimulus isolation unit for use with externally generated stimulation signals. The AC powered stages are photo isolated from the battery powered output stage. The unit is capable of producing bipahsic current and voltage stimulation. The stimulator can be used with the output connections on any PowerLab to control the timing of the stimulator. For 230V/50Hz requires power supply PS-1.
Not for human use.


Add to RFQ

Model: SM-200    Cat.No.: SM-200
Manufacturer: iWORX

Stimulus Isolator.
A constant current Stimulus Isolator with 100 Volt compliance. Specifically designed for safe transcutanious stimulation of muscles. The frequency of pulses produced by the SM-200 may be controlled by any stimulator or digital-to-analog converter capable of producing pulses of three-Volt amplitude.
Electrical stimuli are delivered by the SM-200 to the preparation by way of the high voltage output connectors. One set of high voltage safety connectors is provided with the SM-200 to be used to terminate the lead set of choice. Also included is the SMT-100 striated muscle transducer and exercise manual for the teaching lab.
The stimulator or digital-to-analog converter driving the SM-200 determines duration and frequency of the stimuli delivered to the preparation. A 10-turn dial on the front panel of the SM-200 determines amplitudes.


Add to RFQ
Details

Model: SI-200    Cat.No.: SI-200
Manufacturer: iWORX

Isolated Stimulor.
A high voltage isolated stimulator designed to deliver safe, transcutaneous stimulus pulses to a nerve or a muscle being studied. The design of the SI-200 permits the desired current of the stimulus pulse to be generated despite the impedance on the path that the current follows. The SI-200 adjusts the voltage needed to maintain that current automatically by increasing the voltage that drives the current up to a maximum of 150 volts. Because of this capability, the SI-200 is categorized as a constant current stimulator. However, the current output of the SI-200 is limited to a maximum of 20 milliamperes, with a maximum duration of 10 milliseconds and a maximum frequency of 50Hz. >
Download pdf User Manual.


Add to RFQ

Model: FNS-16    Cat.No.: 16-10000
Manufacturer: Cwe, Inc.

A 16-channel stimulator for neuromuscular stimulation. It features fully programmable bi-phasic, constant-current waveforms, with user control of all timing, polarity, and current amplitude parameters. All outputs are electrically isolated for low noise and to prevent interference with adjacent recordings. Each channel is independently programmable from a host PC, but group of channels can be simultaneously controlled (programmed, stopped or started) for synchronous multi channel stimulation. Download pdf Brochure.
Also is available a 4-channelunit - model FNS-4 (p/n 16-100001). Brochure.


Add to RFQ

Model: DG2A    Cat.No.: DG2A
Manufacturer: Digitimer Ltd.

Train/Delay Generator.
A small free-standing instrument designed for control of normal repetitive stimulation as well as for defining the Effective Refractory Period using a second, delayed pulse. Eespecially useful as a frequency generator for use with our DS2A, DS3 and DS7A isolated stimulators which have their own pulse duration controls.
The basic features of it's predecessor the DG2 Trigger Generator have been extended to allow trains of pulses to be generated in response to input signals from other devices. Download pdf Brochure.


Add to RFQ

Model: DS4    Cat.No.: DS4
Manufacturer: Digitimer Ltd.

Bi-phasic Stimulus Isolator.
The DS4 takes an analogue voltage waveform defined within your own data acquisition/control system and converts it into an isolated constant current stimulus. It accept several input voltage ranges and produces four output ranges (10A, 100A, 1mA and 10mA). It also features a GATE input, so that several DS4 units can be controlled by a single analogue waveform, but enabled individually via this GATE input. A timed "inactivity sensor" reduces battery usage and damaging "leak currents" during infrequent stimulation, while at the same time maintaining low levels of zero crossing distortion for repetitive waveforms. Download pdf Brochure.
DS4 is NOT approved for use on human subjects.


Add to RFQ

Model: Stimulus Isolator    Cat.No.: FE180
Manufacturer: ADInstruments

The Stimulus Isolator uses the analog output from the PowerLab to produce isolated constant-current pulses. The unit is capable of providing isolation and pulse width from 10 s to 2.56 ms with a maximum current of 10 mA. Supplied with black and red shrouded plugs and certified power supply. The unit provides adjustable pulse amplitude, width, and frequency.
The Stimulus Isolator is electronically isolated and approved for human safety and use.


Add to RFQ
Details

Model: MultiStim    Cat.No.: D330
Manufacturer: Digitimer Ltd.

A modular and vesatile Multi-Channel (10-chanel) Stimulator.
System comprises of a 19" Case & Power Supply Unit and a selection of plug-in modules. The system provides either a Constant Voltage stimulation (up to 100V@1A) or Constant Current stimulation (up to 500mA from a 100V source). See list of available modules. Download pdf Brochure.


Add to RFQ
Details

Model: HCS-100    Cat.No.: HCS-100
Manufacturer: iWORX

Stimulator, delivering 50V@0.8A for 1-channel and 50V@0.2A on all four channels.
Thanks to the high output current it is ideal for multiple bath applications or other applications where higher current is desirable. It will output a voltage 10X the input voltage supporting virtually any protocol - Step, Train, Pulse, etc.. Specifications.


Add to RFQ

Model: DS8R    Cat.No.: DS8R
Manufacturer: Digitimer Ltd.

Bipolar Constant Current Stimulator for human research studies.
Involving nerve and muscle stimulation via surface electrodes. It features a high compliance voltage and can be triggered and controlled by multiple external sources. The DS8R can deliver monophasic or biphasic current pulses of up to 2ms duration, with an output range of 2mA to 1000mA* (from 400V).
Notably, the DS8R is the first of our stimulators to feature external “on the fly” control of stimulus pulse parameters, making it possible for stimulation protocols to be semi-automated.
*The actual current achieved will be restricted by a pulse energy limit of 300mJ per pulse and the skin/electrode resistance.
Optional Biphasic, Charge-balanced Output. Download pdf Brochure.

 
2002 © MIROM Medical & Research Equipment Ltd. All rights reserved. Design by PionetWebs Ltd.